The same three projects as Module 3; the client now targets Android and iOS too, and the FieldOps app gains the phone screen of the walkthrough — WorkOrderPage: the blue app bar with FieldOps' own back arrow and FieldOps · Work orders / · WO-4821, the order cards (WO-4821 Riverside Pump Station, WO-4820, WO-4817, WO-4809), the detail with METER READING, NOTES and Submit reading, the Draft restored banner, the Leave WO-4821? Stay / Leave dialog, and the status strip Remote · FieldOps server with the platform on the right.

Run it​

cd "Hybrid and Native Packaging Course/Module 4/FieldOps"
dotnet run -f net10.0 --urls http://localhost:6304
  • Browser, phone layout: open http://localhost:6304 in a window narrower than 600 px (or add ?view=phone).
  • Windows client: as in Module 3 (-p:WindowsPackageType=None for a Remote-only run); with FIELDOPS_URL=http://localhost:6304/?view=phone it opens the phone layout on the desktop.
  • Android emulator: dotnet build -t:Run -f net9.0-android FieldOps.Client\FieldOps.Client.csproj (the client opens http://10.0.2.2:6304/). iOS Simulator: same with -f net9.0-ios, on a Mac.
  • Licence key: FieldOps.Client/HybridLicense.props (git-ignored, see HybridLicense.props.example).

What to try​

ActionExpected result
Phone layout, tap WO-4821Detail full screen: High priority · Pump P-2 inlet, Meter reading, Notes, Submit reading.
Type 412.8 and a note, tap the back arrowLeave WO-4821? The reading 412.8 has not been submitted yet. — Stay keeps you there; Leave discards the draft and pops to the list.
Type a reading, then open FieldOps in a new session (another client or device for the same technician)Opens straight into WO-4821 with Draft restored — WO-4821 · reading 412.8.
In the Hybrid client: minimise / restore (Windows), take a call (phone)Server log lifecycle: …; the draft is saved on Stopped/Backgrounding and restored on Resumed / after the reload.
Android back gestureDevice.Application.BackRequested → the same NavigateBack.
Submit reading with abc"abc" is not a meter reading. Enter a number such as 412.8.
Submit reading with 412.8Reading 412.8 submitted for WO-4821.; back now pops without asking.

What was verified, and how​

  • Builds: FieldOps (net10.0-windows, net10.0); FieldOps.Client + FieldOps.Offline for net9.0-windows10.0.19041.0 and net9.0-android (debug APK com.contoso.fieldops-Signed.apk, 14 MB): 0 errors, 0 warnings. On this machine the Android build needs the workload-manifest workaround described in the course cookbook (a machine problem, not a project setting).
  • Browser (fieldops-m4, 360 × 640): the phone list and detail as in the video; typed 412.8 and a note, back arrow → the Leave dialog; Stay kept the reading; Submit reading → Reading 412.8 submitted for WO-4821.; back then popped to the list without asking.
  • Windows Hybrid client (unpackaged, licensed, phone layout via FIELDOPS_URL): new session → Draft restored — WO-4821 · reading 412.8 (server log + capture of the client window, docs/screenshots/); minimise/restore of my own client window → Deactivated, Stopped, Resumed (draft restored), Activated in the server log.
  • Not run: the Android emulator (no AVD on this machine, none created) and anything iOS (needs a Mac). Therefore Backgrounding, the reload on foreground and BackRequested were not observed — Windows raised neither.

Where this sample differs from the lesson​

  • Project name: the video calls the client FieldOps.Mobile; it is the same FieldOps.Client project from Module 3 with the mobile targets added (the lesson's "one client project").
  • The phone screen is a second page. The desktop list (WorkOrdersPage, Module 3) stays for desktops and wide browsers; WorkOrderPage serves phones, tablets and narrow browsers. Both are the same codebase and the same services.
  • Priority and status labels: Urgent in the video is FieldOps' High; In progress / Complete are On site / Completed. The detail line shows the order's fault ("Pump P-2 inlet").
  • Server address: the 10.0.2.2:5000 is 10.0.2.2:6304, this module's port.
  • The Local fallback stays registered (packaged clients only, see Module 3) although this module's lesson describes FieldOps as Remote; the decision record from Module 1 chose Remote + Local fallback.
  • Windows behaviour: minimise raised Stopped, not Backgrounding, and did not reload the WebView.